Description
-
Parameter
Value
Channel Wavelength
ITU Grid
Channel Spacing
100Ghz
Channel Number
4 Ch
8 Ch
Center wavelength Accuracy (nm)
±0.11
Channel Passband (@-0.5dB bandwidth (nm)
>0.3
Insertion Loss (dB)
In—Drop@drop
2.0
3.2
Add—Out@add
2.0
3.2
In—out@other
2.5
5.0
Add/Drop Channel Ripple (dB)
<0.3
Isolation Channel
Adjacent
>25
Non-adjacent
>45
Inertion Loss Temperature Sensitivity (dB/℃)
<0.005
Wavelength Temperature Shifting (nm/℃)
<0.002
Polarization Dependent Loss (dB)
<0.1
Polarization Mode Dispersion (ps)
<0.1
Directivity (dB) (Input to add, Output to drop,
>50
Return Loss (dB)
>45
Maximum Power Handling (mW)
500
Size
OTU Module
26.5(W)x252(D)x195(H)(mm)
1-slot chassis
482.6(W)x350(D)x43.6(H)(mm)
8-slot chassis
482.6(W)x360(D)x109(H)(mm)
16-slot chassis
482.6(W)x360(D)x261.6(H)(mm)
Opterating Temperature (℃)
-5~+75
Storage Temperature (℃)
-40~85
-
- Optical Add/Drop Multiplexing (OADM)
- Passive OADM-4 , 8, 16 channels
- DWDM C-Band, 100GHz ITU Grid (0.8nm spacing)
- Single-side (east or west) or dual-side (east and west)
- Versatile topology support
- Point-to-point bus
- Low insertion losses
- Power required only for managed applications
- 1-slot design with hot-swap support fits any ST8000 chassis
- Low insertion loss
- Power required only for managed applications and LEDs
ST8000 chassis compatibility:
- Fit ST8000-CH01 1-slot powered chassis
- Fit ST8000-CH08 8-slot powered chassis
-
Fit ST8000-CH16 16-slot powered chassis